In conventional ducted fan design, the motor is secured to the stator hub while the fan secured to the motor shaft. During operation, any imperfection in either the motor or fan will cause both the fan and motor to vibrate at a certain resonance frequency. The oscillation can cause the blade tip to rub against the shroud of the duct. Moto-turbine's 3-bearing system reduces resonance vibration by 90%.
Motor: 2430-3700kv High Performance EDF Brushless
EDF Unit: 64mm
Battery: 11.1v ~ 14.8v (2s ~ 4s MAX)
AMP Draw: 48amp
Watts: 768watts
Thrust: 1040g
ESC: 50amp or greater (Required)
Unit Weight: 160g
Test Data:
11.8v (3s) 2200mah / 29amp / 342watt / 580g Thrust
12.0v (3s) 4400mah / 30amp / 360watt / 610g Thrust
15.2v (4s) 2500mah / 44amp / 669watt / 940g Thrust
16.0v (4s) 5000mah / 48amp / 768watt / 1040g Thrust